BHB、BAM、BAB250℃ Strain Gauge Naming System

Release time:2021-11-10 06:38

1. Strain gauge naming

 

2. Product introduction

  • BHB series

Imported glass fiber reinforced epoxy backing with excellent creep and zero returning performance, low moisture rate ≤0.5%, good humidity resistance, hydrothermal stability ≤45PPM and high response speed. The strain gauges are primarily intended for high accuracy transducers at class 3 or better.

Technical Specifications

 

Thickness of backing(um)

32±5

Thickness of encapsulation(um)

20±2

Backing material

Glass fiber reinforced epoxy

Grid material

Copper foil

Nominal resistance (Ω)

1,203,501,000

Average resistance tolerance

≤±0.15

Gauge factor

2.00~2.20

Dispersion of gauge factor

≤±1

Working temperature range(℃)

-30~+80

STC codes

9,11,16,23,27

Temperature compensation accuracy(um/m/℃)

0.5

Insulation resistance(MΩ)

10000

Strain limit

2.00

fatigue life (±1000)

10000000

 

  • BAM series

Special polyimide film backing with thin thickness, excellent moisture and heat resistance, moisture and heat stability ≤35PPM, low moisture absorption ≤0.6%, good performance of creep and zero returning, easy to paste with certain toughness. The strain gauges are primarily intended for high accuracy transducers at class 3 or better.

Technical Specifications

 

Thickness of backing(um)

30±1

Thickness of encapsulation(um)

30±1

Backing material

Polyimide film

Grid material

Copper foil

Nominal resistance (Ω)

3,506,501,000

Average resistance tolerance

≤±0.1

Gauge factor

2.00~2.20

Dispersion of gauge factor

≤±1

Working temperature rang(℃)

-30~+80

STC codes

9,11,16,23,27

Strain limit%

2

Fatigue life

10000000

Insulation resistance(MΩ)

10000

 

 

 

  • BAB250℃ series

Imported glass fiber reinforced polyimide backing with thin film and good heat resistance/ insulation performance, which is stable and reliable. The strain gauges are primarily intended for high accuracy transducers and high precision component stress analysis within 250℃.

 

Thickness of backing(um)

32±5

Thickness of encapsulation(um)

20±2

Backing material

Glass fiber reinforced polyimide

Grid material

Karma foil

Nominal resistance(Ω)

1,203,501,000

Average resistance tolerance

≤±0.15

Gauge factor

1.86~1.98

Dispersion

of gauge factor

≤±1

Working temperature rang(℃)

-269~+250

STC codes

9,11,16,23,27

Temperature compensation accuracy(um/m/℃)

1

Insulation resistance(MΩ)

10000

Strain limit

1.50%

Fatigue life (±1000)

10000000

 

3. Precautions for use

  • H-600, H-610 high-performance epoxy adhesive is recommended for gage bonding of BHB series and BAM series strain gauge;
  • Please pay attention to control the temperature and welding time during the lead wire welding process. The welding should be quickly applied to avoid damage to the soldering pad and influence to the insulation performance. The recommended soldering temperature is 280℃, with limit of 330℃.
  • The backing material of BHB and BAB series strain gauges is brittle, please be careful during the operation to avoid damage to the strain gauges.
  • If customer has requirement of special lead wire welding, please describe the the corresponding wiring method according to the strain gauge naming system.